Hoshizaki
Hoshizaki KM-1300
Hoshizaki Crescent cuber (KM-1300) used across restaurants, hotels, bars applications.
- Family
- Crescent cuber
- Category
- Ice Machines
- Power
- Electric
Documented fault codes
E01Ice production interruption - harvest cycle timeoutSafe preliminary checks permitted
The control detected the harvest cycle did not complete within the permitted window, so ice making was halted.
E03High pressure cut-outSafe preliminary checks permitted
Refrigerant side pressure exceeded the cut-out limit and the compressor was stopped.
Listed spare parts
HOS-1002-3Replacement assembly for Crescent cuberpotential confirmation required
Blue Dock Parts Supply · United Arab Emirates · unknown
Confirm the exact variant before ordering - an incorrect component can create a hazard.