Ice Machines
E01: Ice production interruption - harvest cycle timeout
Manitowoc UY-0240
Safe preliminary checks permitted
Documented meaning
The control detected the harvest cycle did not complete within the permitted window, so ice making was halted.
Model variants covered: see the model record
Documented possible causes
- · Slow harvest from a restricted water supply
- · Scale build-up on the evaporator
- · Bin control or curtain sensor not closing
Safe preliminary checks
- · Confirm the water supply valve is fully open and the filter is not blocked
Professional service required
- · Confirm the water supply valve is fully open and the filter is not blocked
- · Check that the bin curtain or sensor moves freely
- · Reset the machine once and observe whether the cycle completes
- · professional_only
Stop and call a professional if you see
- · Burning smell, smoke, water on live parts or a tripped protective device
- · Unusual noise, vibration or a refrigerant leak